Design and Construction of Air Quality Monitoring System using Node MCU IoT Based

Vivi Wulandari - Departement of physics, Universitas Negeri Padang, Jl. Prof. Dr. Hamka Air Tawar Padang 25131
- Yohandri - Departement of physics, Universitas Negeri Padang, Jl. Prof. Dr. Hamka Air Tawar Padang 25131

Abstract


Air as a natural resource affects human life and other natural resources. Air consists of about 78% Nitrogen, 20% Oxygen, 1.07% consists of Neon (Ne), Helium (He), Methane (CH4) and Hydrogen (H2), 0.9% Argon and the remaining 0.03% Carbon Dioxide (CO2). This research is a type of engineering research. Data collection was carried out by direct measurement. For direct data collection, it was carried out by monitoring levels of CO2, CO, temperature, and humidity, for data collection from each parameter, 5 variations were given for measurement. Based on the objectives of the research, the results of the design specifications of the tool are obtained, namely the percentage level of accuracy of the average measurement produced by air quality monitoring which is 97.78%, the average percentage of relative error obtained is 2.24%. Therefore, it can be concluded that the specifications for the performance of the tool are that the components that make up the tool can work well

References


Andrizal. Putri Indah Yani. Yul Antonisfia. 2020. "Monitoring Dan Kontrol Kadar CO2 Dalam Ruangan Berbasis Sistem Penciuman Elektronik". Jurnal Seminar NasionalTerapan Riset Inovatif (SENTRINOV) Series : Engineering and Science , Vol 6 (1):388-395.

Jaya, Agus Indra 2011. "Mencari Perluasan Model Dinamik Unsur-Unsur Utama Iklim".Jurnal Ilmiah Matematika dan Terapan, Vol 8 (1).

Astuti, Irnin Agustina Dwi, Firdaus. 2017."Analisis Kandungan CO2 Dengan Sensor Dan Berbasis Logger Pro Di Daerah Yogyakarta". Jurnal Inovasi Pendidikan Fisika danRiset Ilmiah, Vol 1(1), 5-8.

IPCC Climate Change, (2007). The Physical Science Basis Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change.

Rahim, Ramli., dkk. 2016. Karakteristik Data Temperatur Udara Dan Kenyamanan Termal di Makassar. e-Prossiding Temu Ilmiah IPLBI.

Fauziah, Dhita Ayu, Mursid Rahardjo, Nikie A. Y. D. 2017. "Analisis Tingkat Pencemaran Udara Di Terminal Kota Semarang". Jurnal Kesehatan Masyarakat, Vol 5 (5).

Virdaus, Muchamad Seno Sahisnu, Eko Ihsanto. 2021. "Rancang Bangun Monitoring Dan Kontrol Kualitas Udara Dengan Metode Fuzzy Logic Berbasis Wemos". JurnalTeknologi Elektro, Vol. 12 (1): 22-28.

Prasetyo, Dwi, Ibrahim, Lamada, Wilma, Nurul, Adzillah. 2021. "Implementasi

Monitoring Kualitas Udara Menggunakan MQ-7 dan MQ-131 Berbasis Internet ofThings". Jurnal Rekayasa dan Teknologi Elektro, Vol. 15 (3).

Tobari, MC Kota Padang. 2019. "ISPU Kota Padang Capai Nilai 67",(online), ( https://infopublik.id/kategori/nusantara/375249/ispu-kota-padang-capai-nilai- diakses 15 November 2021.

Amsar. Khairuman. Marlina. 2020. "Perancangan Alat Pendeteksi CO2 Menggunakan Sensor MQ-2 Berbasis Internet Of Things". Jurnal Manajemen Informatika & Komputerisasi Akuntansi (METHOMIKA), Vol 4 (1):73-79.

Faradilla, Chyntia. 2020. "Monitoring Dan Kandungan Gas Udara Kering CO, CO2 Pada Ruangan Tertutup Berbasis Mikrokontroler". Tugas Akhir. Padang: Jurusan TeknikElektro.

Cooper, WD. 1999. Instrumentasi Elektronika dan Teknik pengukuran. Jakarta : Erlangga.

Andrizal. Putri Indah Yani. Yul Antonisfia. 2020. "Monitoring Dan Kontrol Kadar CO2 Dalam Ruangan Berbasis Sistem Penciuman Elektronik". Jurnal Seminar NasionalTerapan Riset Inovatif (SENTRINOV) Series : Engineering and Science , Vol 6 (1):388-395.

Mulyanah, Elwin. Hellyana, Mei Corie. 2015. "Perancangan Dan Pembuatan Alat Pengering Kerupuk Otomatis Menggunakan Mikrokontroler atmega 16". Jurnal Evolusi, Vol 3(2): 45.

Susilawati, Helfy, Ade, Rukmana, Jonhari, Apip. 2020. "Rancang Bangun Prototype Monitoring Kadar Gas CO, CO2, CH4 Berbasis Mikrokontroler Atmega 328P di Ruangan Laboratorium". Vol 11

N, Rosman Andi. 2017. "Perancangan Power Supply 4.5 Dan 11.5 Volt Menggunakan Rangkaian Regulator Zener Follower". Jurnal Scientific Pinisi, Vol 3 (1): 55-59.

Azrol Bin Azahar, M., Shamian Zainal, M., Shahidah Mohd Shah, N., Md Nor, D., Anuar Hamzah, S., & Mohamed, M. (2020). IoT-Based Air Quality Device for Smart Pollution Monitoring. Progress in Engineering Application and Technology, 1(1), 284–295. https://doi.org/10.30880/peat.2020.01.01.031

Jaber, A. A., Al-Mousawi, F. K. I., & Jasem, H. S. (2019). Internet of things based industrial environment monitoring and control: A design approach. International Journal of Electrical and Computer Engineering, 9(6), 4657–4667. https://doi.org/10.11591/ijece.v9i6.pp4657-4667

Kristiyana, S., & Rinaldi, A. (2020). Air Quality Monitoring System in Thingspeak-Based Applications Using Internet of Things (IOT). WSEAS TRANSACTIONS ON COMPUTER RESEARCH, 8, 34–38. https://doi.org/10.37394/232018.2020.8.6

Murad, S. A. Z., Bakar, F. A., Azizan, A., & Shukri, M. A. M. (2021). Design of Internet of Things Based Air Pollution Monitoring System Using ThingSpeak and Blynk Application. Journal of Physics: Conference Series, 1962(1). https://doi.org/10.1088/1742-6596/1962/1/012062

Nasution, T. H., Muchtar, M. A., & Simon, A. (2019). Designing an IoT-based air quality monitoring system. IOP Conference Series: Materials Science and Engineering, 648(1). https://doi.org/10.1088/1757-899X/648/1/012037




DOI: http://dx.doi.org/10.24036/13471171074