Cover Image

Evaluasi Struktur Bangunan Pasar Inpress Blok IV Gedung B dengan Metode Pushover

Lisyana Junelin Restu, Eka Juliafad, Fajri Yusmar

Abstract


Abstract

Inpres market block IV Pasar Raya Padang is not designed as a shelter building, but is designated as a vertical evacuation site when a tsunami occurs. This study aims to evaluate the structural performance of Inpress market block IV zone B. The method used for this research is the pushover analysis method. According to FEMA P-646/2019, vertical evacuation refuge structures are included in tsunami risk category IV, based on the risk category the maximum performance level is at the Immediate Occupancy (IO). For loads on buildings, refer to SNI 1727:2020 and SNI 1726:2019 for earthquake loads. For the calculation of the capacity of concrete structural elements, refer to SNI 2847:2019. Structural analysis was carried out using the SAP2000 version 16. After analysis, based on performance points, drift ratio that occur due to earthquake loading in X-direction and Y-direction are 0,05875% and 0,0067%. The maximum total drift that occurs is smaller than that required by ATC-40 for the Immediate Occupancy performance level, which is 1%. Thus, the structure performance level is Immediate Occupancy. This means that the Inpress market block IV building is still strong enough against earthquake loads.


Keywords


Earthquake, pushover analysis, performance level, vertical evacuation refuge structures

Full Text:

PDF

References


BNPB Editorial, “Refleksi Tsunami 1797,” 2020.

E. Juliafad, “Study on The Environmental System towards The Development of Assessment Tools for Disaster Reduction of Reinforced Concrete Building due to Future Mega-Earthquake in Padang City , Indonesia .,” 2017.

Federal Emergency Management Agency P-646, Guidelines for Design of Structures for Vertical Evacuation From Tsunamis 3rd Edition, no. August. 2019.

E. Juliafad and A. P. Melinda, “Assessment of Reinforced Concrete Building for Disaster Reduction Strategy in Padang City , West Sumatra , Indonesia.”

E. Juliafad, K. Meguro, and G. Hideomi, “Study on The Environmental System towards The Development of Assessment Tools for Disaster Reduction of Reinforced Concrete Building due to Future Mega-Earthquake in Padang City , Indonesia .,” Seisan Kenkyu, 2017.

ATC-40, Seismic Evaluation and Retrofit of Concrete Buildings. 1996.

A. Marwanto, Ary; Budi, Agus; Supriyadi, “Evaluasi Kinerja Struktur Gedung 10 Lantai dengan Analisis Pushover Terhadap Drift dan Displacement Menggunakan Software ETABS,” e-Jurnal MATRIKS Tek. SIPIL, no. September, pp. 484–491, 2014.

Iskandar, “Analisis Pushover Struktur Baja Pada Wilayah Gempa Kuat (6) dengan Studi Kasus Struktur Bangunan Baja Beraturan,” J. Portal, vol. 5, no. 1, pp. 40–50, 2013.

L. Budiono, Bambang; Supriatna, Studi Komparasi Desain Bangunan Tahan Gempa dengan Menggunakan SNI 03-1726-2002 dan RSNI 03-1726-201x. Bandung: Penerbit ITB, 2016.

R. Ahmad, Analisis Kinerja Seismik Struktur Beton dengan Metode Pushover Menggunakan Program SAP2000 V.14. Mataram, 2016.

SNI 1726-2019, Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan nongedung. Jakarta: Badan Standardisasi Nasional, 2019.




DOI: https://doi.org/10.24036/cived.v8i3.113638

Copyright (c) 2021 Lisyana Junelin Restu, Eka Juliafad, Fajri Yusmar

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

PENERBIT : UNIVERSITAS NEGERI PADANG

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Alamat:
Jalan Hamka  Padang. Indonesia
email: sipil@ft.unp.ac.id